Toshiba VF-AS1 Error Code E41

Toshiba PLC & VFD Minor Frequency

Model: VF-AS1 | Code: E41

Applicable Systems
VF-AS1

Symptoms

The VF-AS1 reports an over-frequency fault. The output frequency exceeded the maximum configured frequency limit.

Possible Causes

  • Frequency command exceeding the maximum frequency parameter setting
  • External analog reference input exceeding the maximum scale
  • Maximum frequency parameter set incorrectly for the application

Troubleshooting Steps

  1. Step 1: Check the frequency command source for values exceeding the limit
    Command is within the frequency limit
  2. Step 2: Verify the maximum frequency parameter is set correctly
    Maximum frequency matches the motor rating
  3. Step 3: Scale the analog reference input to the correct range
    Reference input is scaled correctly

How to Reset

To reset: Reduce the frequency below the limit, then reset the fault.

Source: Toshiba VF-AS1 Inverter Manual, Toshiba Mitsubishi-Electric Industrial Systems

Category: PLC & VFD