Universal Robots e-Series Error Code C263A41: The rate of invalid samples is too high. Debt counter = {unsigned}

Universal Robots Robot Minor System

Model: e-Series (UR3e/UR5e/UR10e/UR16e/UR20/UR30) | Code: C263A41

Applicable Systems
UR3 UR5 UR10 UR3e UR5e UR10e UR16e UR20 UR30

Symptoms

A high rate of invalid samples can indicate a faulty motor encoder, a bad connection, or an EMC/ESD issue.

Possible Causes

  • A high rate of invalid samples can indicate a faulty motor encoder, a bad connection, or an EMC/ESD issue.

Troubleshooting Steps

  1. Step 1: Conduct a complete rebooting sequence,
    Check if the issue is resolved after this step
  2. Step 2: Check for possible EM noise or ESD sources,
    Check if the issue is resolved after this step
  3. Step 3: Update software,
    Check if the issue is resolved after this step
  4. Step 4: Contact your local Universal Robots service provider for assistance
    Check if the issue is resolved after this step

How to Reset

Power cycle the robot controller and perform a complete reboot sequence. If the error persists, update the software to the latest version.