Universal Robots e-Series Error Code C265A47: Magnetic pattern decoding error

Universal Robots Robot Major System

Model: e-Series (UR3e/UR5e/UR10e/UR16e/UR20/UR30) | Code: C265A47

Applicable Systems
UR3 UR5 UR10 UR3e UR5e UR10e UR16e UR20 UR30

Symptoms

A stray magnetic field is present or metal particles are present between the read head and the ring or radial positioning between the read head and the ring is out of tolerances.

Possible Causes

  • A stray magnetic field is present or metal particles are present between the read head and the ring or radial positioning between the read head and the ring is out of tolerances.

Troubleshooting Steps

  1. Step 1: Remove any sources of magnetic fields external to the robot, and conduct a complete rebooting sequence,
    Check if the issue is resolved after this step
  2. Step 2: Update software,
    Check if the issue is resolved after this step
  3. Step 3: Contact your local Universal Robots service provider for assistance
    Check if the issue is resolved after this step

How to Reset

Power cycle the robot controller and perform a complete reboot sequence. If the error persists, update the software to the latest version.

Source: Universal Robots Official Error Codes Directory (https://www.universal-robots.com/manuals/EN/PDF/Shared/ErrorCodes/ErrorCodes.pdf)