Worcester Bosch Greenstar GB162 Error Code WB01

Worcester Bosch Home Boiler Critical Ignition

Model: Greenstar GB162 | Code: WB01

Applicable Systems
Greenstar GB162

Symptoms

The boiler reports an ignition failure. The burner failed to ignite after the ignition sequence.

Possible Causes

  • Gas supply pressure too low or no gas
  • Ignition electrode worn or mispositioned
  • Ignition transformer or spark generator failure

Troubleshooting Steps

  1. Step 1: Check the gas supply pressure at the boiler inlet
    Pressure meets the minimum requirement
  2. Step 2: Inspect the ignition electrode for wear and position
    Electrode is clean and correctly gapped
  3. Step 3: Test the ignition transformer output
    Transformer produces a strong spark

How to Reset

To reset: Resolve the ignition issue, then press the reset button on the boiler.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Worcester Bosch Boiler Manual, Worcester Bosch Group

Category: Home Boiler