321-15 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 321 FMI 15 - Brake Oil Pressure (Low) Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
252-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 252 FMI 8 - Fuel Injector (Cylinder 2) Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
CID-21-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 21 FMI 2 - ECM Power Supply: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Critical |
View → |
CID-47-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 47 FMI 6 - Turbocharger Compressor Outlet Temperature: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Major |
View → |
3-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 3 FMI 0 - Injection Actuation Pressure Sensor Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
CID-158-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 158 FMI 5 - Armrest Position Switch: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
441-3 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 441 FMI 3 - Engine Warning Indicator Circuit Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
111-15 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 111 FMI 15 - Battery Voltage Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
CID-44-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 44 FMI 4 - Crankcase Pressure: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
415-16 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 415 FMI 16 - Engine Oil Level (Low) Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-200-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 200 FMI 0 - Work Tool Calibration: Data Valid But Above Normal Operational Range |
heavy-equipment |
Minor |
View → |
471-17 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 471 FMI 17 - Engine Over-speed Protection Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
58-3 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 58 FMI 3 - Analog Temperature Sensor Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
110-15 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 15 - Radiator Coolant Temperature Sensor Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
168-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 168 FMI 5 - Engine ECM Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
46-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 46 FMI 6 - ECM Connector (Rack Sensor) Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
42-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 42 FMI 13 - Engine Oil Temperature Sensor Out of Calibration |
heavy-equipment |
Minor |
View → |
35-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 35 FMI 0 - Radiator Coolant Level Sensor Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
255-3 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 255 FMI 3 - Fuel Injector (Cylinder 5) Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
CID-162-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 162 FMI 4 - Joystick Position #4: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-163-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 163 FMI 5 - Pedal Position #1: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-84-FMI-13 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 84 FMI 13 - Cylinder Cutout #1: Out of Calibration |
heavy-equipment |
Major |
View → |
38-2 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 38 FMI 2 - Fuel Temperature Sensor Data Erratic/Intermittent |
heavy-equipment |
Minor |
View → |
CID-107-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 107 FMI 4 - Fan Control Solenoid: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
CID-176-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 176 FMI 3 - Shear Mode Switch: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
40-2 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 40 FMI 2 - Engine Oil Level Sensor Data Erratic/Intermittent |
heavy-equipment |
Minor |
View → |
CID-115-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 115 FMI 0 - Final Drive Oil Temperature: Data Valid But Above Normal Operational Range |
heavy-equipment |
Minor |
View → |
411-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 411 FMI 18 - Radiator Coolant Level (Low) Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
35-15 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 35 FMI 15 - Radiator Coolant Level Sensor Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
241-16 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 241 FMI 16 - Engine Speed-Timing Sensor (Camshaft) Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
361-3 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 361 FMI 3 - Engine Oil Temperature (High) Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
CID-81-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 81 FMI 2 - Timing Sensor: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Critical |
View → |
CID-154-FMI-8 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 154 FMI 8 - Remote Shutdown Command: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Critical |
View → |
71-15 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 71 FMI 15 - Fuel Injection Quantity Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
401-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 401 FMI 13 - Alternator Not Charging Out of Calibration |
heavy-equipment |
Minor |
View → |
CID-4-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 4 FMI 4 - Fuel Pressure: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
2-16 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 2 FMI 16 - Engine Speed-Timing Sensor Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-195-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 195 FMI 3 - Work Tool Cycle Count: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-185-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 185 FMI 0 - Attachment Flow: Data Valid But Above Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-145-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 145 FMI 0 - Machine Pitch Angle: Data Valid But Above Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-26-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 26 FMI 3 - Sensor Supply Voltage 8V: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
91-2 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 91 FMI 2 - Injection Actuation Pressure Control Valve (Open) Data Erratic/Intermittent |
heavy-equipment |
Minor |
View → |
CID-37-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 37 FMI 6 - Alternator Output: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Major |
View → |
CID-53-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 53 FMI 6 - SCR Dosing Unit: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Major |
View → |
251-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 251 FMI 5 - Fuel Injector (Cylinder 1) Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
CID-44-FMI-13 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 44 FMI 13 - Crankcase Pressure: Out of Calibration |
heavy-equipment |
Major |
View → |
16-2 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 16 FMI 2 - Engine Oil Pressure Sensor Data Erratic/Intermittent |
heavy-equipment |
Minor |
View → |
CID-91-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 91 FMI 4 - Engine Serial Number: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
CID-114-FMI-13 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 114 FMI 13 - Axle Oil Pressure: Out of Calibration |
heavy-equipment |
Minor |
View → |
253-16 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 253 FMI 16 - Fuel Injector (Cylinder 3) Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-64-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 64 FMI 5 - Engine Brake Solenoid #1: Current Below Normal, or Open Circuit |
heavy-equipment |
Major |
View → |
281-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 281 FMI 18 - Transmission Speed Sensor Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-27-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 27 FMI 4 - Vehicle Speed: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
291-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 291 FMI 8 - Transmission Temperature Sensor Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
281-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 281 FMI 13 - Transmission Speed Sensor Out of Calibration |
heavy-equipment |
Minor |
View → |
CID-120-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 120 FMI 0 - Implement Pump Pressure: Data Valid But Above Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-3-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 3 FMI 5 - Engine Speed/Timing: Current Below Normal, or Open Circuit |
heavy-equipment |
Critical |
View → |
CID-195-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 195 FMI 0 - Work Tool Cycle Count: Data Valid But Above Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-195-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 195 FMI 2 - Work Tool Cycle Count: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
35-17 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 35 FMI 17 - Radiator Coolant Level Sensor Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
CID-30-FMI-1 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 30 FMI 1 - Transmission Oil Pressure: Data Valid But Below Normal Operational Range |
heavy-equipment |
Major |
View → |
CID-117-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 117 FMI 4 - Swing Brake Oil Pressure: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
361-15 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 361 FMI 15 - Engine Oil Temperature (High) Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
CID-106-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 106 FMI 3 - Desired Fan Speed: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
451-16 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 451 FMI 16 - Air Filter Restriction (High) Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-123-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 123 FMI 3 - Charge Pump Pressure: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-127-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 127 FMI 3 - Boom Cylinder Rod Pressure: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-18-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 18 FMI 4 - Fuel Injector #4: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
CID-137-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 137 FMI 3 - Bucket Position Sensor: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
41-3 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 41 FMI 3 - Air Inlet Heater Relay Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
461-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 461 FMI 8 - Fuel Water Separator Sensor Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
451-17 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 451 FMI 17 - Air Filter Restriction (High) Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
CID-189-FMI-8 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 189 FMI 8 - Work Tool Pump Flow: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Minor |
View → |
321-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 321 FMI 5 - Brake Oil Pressure (Low) Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
CID-100-FMI-1 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 100 FMI 1 - Average Fuel Rate: Data Valid But Below Normal Operational Range |
heavy-equipment |
Minor |
View → |
41-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 41 FMI 8 - Air Inlet Heater Relay Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
172-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 172 FMI 18 - Fuel Injection Actuation Pressure (High) Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |