E7001 |
Case |
CX210 Excavator
|
Case CX210 Excavator Error Code E7001 |
heavy-equipment |
Critical |
View → |
E7008 |
Case |
CX210 Excavator
|
Case CX210 Excavator Error Code E7008 |
heavy-equipment |
Critical |
View → |
E7010 |
Case |
CX210 Excavator
|
Case CX210 Excavator Error Code E7010 |
heavy-equipment |
Major |
View → |
E7014 |
Case |
CX210 Excavator
|
Case CX210 Excavator Error Code E7014 |
heavy-equipment |
Critical |
View → |
H7003 |
Case |
CX210 Excavator
|
Case CX210 Excavator Error Code H7003 |
heavy-equipment |
Major |
View → |
H7004 |
Case |
CX210 Excavator
|
Case CX210 Excavator Error Code H7004 |
heavy-equipment |
Critical |
View → |
H7006 |
Case |
621G Loader
|
Case 621G Loader Error Code H7006 |
heavy-equipment |
Minor |
View → |
T7005 |
Case |
621G Loader
|
Case 621G Loader Error Code T7005 |
heavy-equipment |
Major |
View → |
451-2 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 451 FMI 2 - Air Filter Restriction (High) Data Erratic/Intermittent |
heavy-equipment |
Minor |
View → |
111-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 111 FMI 6 - Battery Voltage Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
255-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 255 FMI 13 - Fuel Injector (Cylinder 5) Out of Calibration |
heavy-equipment |
Minor |
View → |
CID-4-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 4 FMI 6 - Fuel Pressure: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Major |
View → |
381-17 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 381 FMI 17 - Engine Air Filter Restriction Switch Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
491-4 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 491 FMI 4 - Transmission Filter Bypass Switch Voltage Below Normal/Shorted Low |
heavy-equipment |
Major |
View → |
58-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 58 FMI 0 - Analog Temperature Sensor Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
CID-62-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 62 FMI 3 - EGR Differential Pressure: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
61-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 61 FMI 13 - Alternator (Field Current) Out of Calibration |
heavy-equipment |
Minor |
View → |
CID-41-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 41 FMI 3 - Engine Overspeed: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Critical |
View → |
CID-44-FMI-8 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 44 FMI 8 - Crankcase Pressure: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Major |
View → |
CID-94-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 94 FMI 5 - Engine Run Time: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
55-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 55 FMI 5 - Injection Actuation Pressure Control Valve (Current) Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
CID-109-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 109 FMI 4 - Fuel Filter Differential Pressure: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-74-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 74 FMI 4 - Desired Throttle Position: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
CID-158-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 158 FMI 3 - Armrest Position Switch: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-197-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 197 FMI 5 - Work Tool Service Interval: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
371-16 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 371 FMI 16 - Fuel Filter Differential Pressure Switch Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
471-4 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 471 FMI 4 - Engine Over-speed Protection Voltage Below Normal/Shorted Low |
heavy-equipment |
Major |
View → |
CID-1-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 1 FMI 3 - Engine Oil Pressure: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
CID-157-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 157 FMI 4 - Seat Belt Switch: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
100-4 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 100 FMI 4 - Engine Controller (ECM) Power Voltage Below Normal/Shorted Low |
heavy-equipment |
Major |
View → |
381-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 381 FMI 6 - Engine Air Filter Restriction Switch Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
51-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 51 FMI 6 - Engine Speed-Timing Sensor (Rack Position) Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
251-17 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 251 FMI 17 - Fuel Injector (Cylinder 1) Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
42-15 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 42 FMI 15 - Engine Oil Temperature Sensor Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
321-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 321 FMI 1 - Brake Oil Pressure (Low) Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
CID-60-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 60 FMI 3 - EGR Valve Position: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
CID-189-FMI-13 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 189 FMI 13 - Work Tool Pump Flow: Out of Calibration |
heavy-equipment |
Minor |
View → |
CID-97-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 97 FMI 3 - Total Idle Fuel Used: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
241-15 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 241 FMI 15 - Engine Speed-Timing Sensor (Camshaft) Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
421-4 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 421 FMI 4 - Transmission Oil Level (Low) Voltage Below Normal/Shorted Low |
heavy-equipment |
Major |
View → |
CID-81-FMI-1 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 81 FMI 1 - Timing Sensor: Data Valid But Below Normal Operational Range |
heavy-equipment |
Critical |
View → |
CID-142-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 142 FMI 4 - Stick Angle: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
26-2 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 26 FMI 2 - Inlet Manifold Pressure Sensor Data Erratic/Intermittent |
heavy-equipment |
Minor |
View → |
CID-41-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 41 FMI 2 - Engine Overspeed: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Critical |
View → |
17-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 17 FMI 8 - Alternator (Battery Voltage) Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
321-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 321 FMI 13 - Brake Oil Pressure (Low) Out of Calibration |
heavy-equipment |
Minor |
View → |
CID-60-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 60 FMI 4 - EGR Valve Position: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
415-15 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 415 FMI 15 - Engine Oil Level (Low) Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
CID-23-FMI-8 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 23 FMI 8 - ECM Communication: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Major |
View → |
CID-193-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 193 FMI 4 - Work Tool Position: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-180-FMI-1 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 180 FMI 1 - Quick Coupler Switch: Data Valid But Below Normal Operational Range |
heavy-equipment |
Minor |
View → |
4-15 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 4 FMI 15 - Engine Coolant Temperature Sensor Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
61-15 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 61 FMI 15 - Alternator (Field Current) Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
CID-16-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 16 FMI 2 - Fuel Injector #2: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |
CID-197-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 197 FMI 6 - Work Tool Service Interval: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
415-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 415 FMI 5 - Engine Oil Level (Low) Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
55-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 55 FMI 18 - Injection Actuation Pressure Control Valve (Current) Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
78-3 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 78 FMI 3 - Engine Speed-Timing Sensor (Crankshaft) Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
401-3 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 401 FMI 3 - Alternator Not Charging Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
42-3 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 42 FMI 3 - Engine Oil Temperature Sensor Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
CID-50-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 50 FMI 2 - Particulate Trap Differential Pressure: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |
CID-22-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 22 FMI 4 - ECM Memory: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Critical |
View → |
200-17 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 200 FMI 17 - Engine Oil Pressure (Low) Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
336-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 336 FMI 13 - Hydraulic Pump Pressure Sensor Out of Calibration |
heavy-equipment |
Minor |
View → |
253-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 253 FMI 13 - Fuel Injector (Cylinder 3) Out of Calibration |
heavy-equipment |
Minor |
View → |
381-15 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 381 FMI 15 - Engine Air Filter Restriction Switch Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
CID-67-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 67 FMI 3 - Fan Drive Solenoid: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
481-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 481 FMI 5 - Hydraulic Filter Restriction Switch Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
441-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 441 FMI 1 - Engine Warning Indicator Circuit Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
CID-155-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 155 FMI 4 - Theft Deterrent System: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
110-3 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 3 - Radiator Coolant Temperature Sensor Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
CID-159-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 159 FMI 5 - Joystick Position #1: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-77-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 77 FMI 4 - Injection Actuation Pressure: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Critical |
View → |
CID-35-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 35 FMI 4 - Hydraulic Fan Solenoid: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
46-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 46 FMI 8 - ECM Connector (Rack Sensor) Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
371-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 371 FMI 5 - Fuel Filter Differential Pressure Switch Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
CID-107-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 107 FMI 5 - Fan Control Solenoid: Current Below Normal, or Open Circuit |
heavy-equipment |
Major |
View → |