Applicable Systems
GA Series Compressed Air System

Symptoms

The compressor reports an oil separator clogged. The oil separator element has excessive pressure drop.

Possible Causes

  • Separator element saturated with oil and contaminants
  • Element at end of service life
  • Oil carry-over rate too high overwhelming the separator

Troubleshooting Steps

  1. Step 1: Measure pressure drop across the separator
    Drop exceeds the replacement threshold
  2. Step 2: Replace the oil separator element
    New element is installed correctly
  3. Step 3: Verify oil carry-over is within normal range
    Oil consumption is within specification

How to Reset

To reset: Replace the oil separator, then clear the alarm.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Atlas Copco Compressor Manual, Atlas Copco AB