Applicable Systems
GA Series Compressed Air System

Symptoms

The compressor reports a minimum pressure valve fault. The minimum pressure valve is not maintaining the minimum system pressure.

Possible Causes

  • Valve seat worn causing leakage
  • Valve spring broken or fatigued
  • Valve piston stuck from contamination

Troubleshooting Steps

  1. Step 1: Inspect the valve seat for wear
    Seat is smooth and seals correctly
  2. Step 2: Check the valve spring condition
    Spring is intact with correct tension
  3. Step 3: Clean and verify the valve piston movement
    Piston moves freely

How to Reset

To reset: Repair or replace the minimum pressure valve, then clear the alarm.

Source: Atlas Copco Compressor Manual, Atlas Copco AB

Category: Hydraulic & Pneumatic