Applicable Systems
GA Series Compressed Air System

Symptoms

The compressor reports a safety valve activation. The system safety valve has opened to relieve excess pressure.

Possible Causes

  • System pressure exceeded the safety valve setpoint
  • Safety valve setpoint drifted too low
  • Safety valve seat damaged causing premature opening

Troubleshooting Steps

  1. Step 1: Investigate and correct the overpressure cause
    System pressure returns to normal
  2. Step 2: Verify the safety valve setpoint
    Setpoint matches the system specification
  3. Step 3: Replace the safety valve if it does not reseat
    New valve seals and holds pressure

How to Reset

To reset: Resolve the overpressure, reseat or replace the safety valve, then clear the alarm.

Source: Atlas Copco Compressor Manual, Atlas Copco AB

Category: Hydraulic & Pneumatic