Baldor MicroFlex Error Code B012

Baldor PLC & VFD Major Speed

Model: MicroFlex | Code: B012

Applicable Systems
MicroFlex

Symptoms

The MicroFlex reports an overspeed fault. The motor speed exceeded the overspeed threshold, indicating loss of speed control.

Possible Causes

  • Speed command exceeding the motor rated maximum speed
  • Load runaway due to gravity or external force overpowering the brake
  • Speed feedback signal error causing false overspeed detection

Troubleshooting Steps

  1. Step 1: Check the speed command source for excessive values in the drive
    Speed command is within the valid range
  2. Step 2: Verify the brake is holding when the motor is stopped
    Brake holds the load without slipping
  3. Step 3: Check the encoder signal for noise or missing pulses
    Encoder signal is clean and accurate

How to Reset

To reset: Reduce speed to within limits, then reset the fault.

Source: Baldor MicroFlex Drive Manual, Baldor Electric Company/ABB

Category: PLC & VFD