Baldor MicroFlex Error Code B012

Baldor PLC & VFD Major Speed

Model: MicroFlex | Code: B012

Applicable Systems
MicroFlex

Symptoms

The MicroFlex reports an overspeed fault. The motor speed exceeded the overspeed threshold, indicating loss of speed control.

Possible Causes

  • Speed command exceeding the motor rated maximum speed
  • Load runaway due to gravity or external force overpowering the brake
  • Speed feedback signal error causing false overspeed detection

Troubleshooting Steps

  1. Step 1: Check the speed command source for excessive values in the drive
    Speed command is within the valid range
  2. Step 2: Verify the brake is holding when the motor is stopped
    Brake holds the load without slipping
  3. Step 3: Check the encoder signal for noise or missing pulses
    Encoder signal is clean and accurate

How to Reset

To reset: Reduce speed to within limits, then reset the fault.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Baldor MicroFlex Drive Manual, Baldor Electric Company/ABB

Category: PLC & VFD