Applicable Systems
Pack 301

Symptoms

The packaging machine reports a packaging count error. The actual package count does not match the set count target.

Possible Causes

  • Product feed timing inconsistent
  • Count sensor missing or double-counting products
  • Machine speed variation affecting count accuracy

Troubleshooting Steps

  1. Step 1: Verify product feed timing and spacing
    Products are consistently spaced
  2. Step 2: Check the count sensor for reliable detection
    Sensor detects each product accurately
  3. Step 3: Verify machine speed stability during counting
    Speed is stable within tolerance

How to Reset

To reset: Correct the counting issue, then clear the alarm on the HMI.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Bosch Packaging Machine Manual, Bosch Packaging Technology

Category: Packaging