Applicable Systems
Pack 301
Symptoms
The packaging machine reports a packaging count error. The actual package count does not match the set count target.
Possible Causes
- Product feed timing inconsistent
- Count sensor missing or double-counting products
- Machine speed variation affecting count accuracy
Troubleshooting Steps
- Step 1: Verify product feed timing and spacing
Products are consistently spaced - Step 2: Check the count sensor for reliable detection
Sensor detects each product accurately - Step 3: Verify machine speed stability during counting
Speed is stable within tolerance
How to Reset
To reset: Correct the counting issue, then clear the alarm on the HMI.
Source: Bosch Packaging Machine Manual, Bosch Packaging Technology
Category: Packaging