Applicable Systems
Pack 301

Symptoms

The packaging machine reports a temperature control anomaly. A sealing or forming temperature is outside the acceptable tolerance band.

Possible Causes

  • Heater element burned out or not energizing
  • Temperature controller PID tuning issue
  • Thermocouple or RTD sensor drifted or failed

Troubleshooting Steps

  1. Step 1: Check the heater element for continuity and proper resistance
    Heater shows correct resistance and energizes
  2. Step 2: Verify the thermocouple or RTD reading against a reference
    Sensor reads accurately within tolerance
  3. Step 3: Tune the PID parameters for stable temperature control
    Temperature holds at setpoint without oscillation

How to Reset

To reset: Resolve the temperature control issue, then clear the alarm.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Bosch Packaging Machine Manual, Bosch Packaging Technology