Bosch Rexroth IndraDrive Error Code C0920

Bosch Rexroth PLC & VFD Major Safety

Model: IndraDrive | Code: C0920

Applicable Systems
IndraDrive

Symptoms

The IndraDrive reports a safety function activation. The safety circuit was triggered, removing motor torque and halting the drive.

Possible Causes

  • Safety input signal activated by an external safety relay or E-stop
  • Safety relay wiring fault causing false trigger
  • Safety function configuration does not match the application requirements

Troubleshooting Steps

  1. Step 1: Check the safety input wiring and verify the safety relay status
    Safety relay is in the expected state
  2. Step 2: Verify the safety function configuration parameters in the drive
    Safety configuration matches the application
  3. Step 3: Reset the safety circuit by clearing the E-stop and cycling the safety relay
    Safety function releases and motor torque is restored

How to Reset

To reset: Clear the safety condition and reset the safety relay, then restart.

Source: Bosch Rexroth IndraDrive Functional Description, Bosch Rexroth AG

Category: PLC & VFD