Demag DR-PRO 50t Error Code D001

Demag Crane Critical Safety

Model: DR-PRO 50t | Code: D001

Applicable Systems
DR-PRO 50t

Symptoms

The crane reports a hoist overload. The lifted load exceeds the rated capacity of the rope hoist.

Possible Causes

  • Load weight exceeding the hoist rated capacity
  • Load cell calibration error giving false reading
  • Dynamic loading from sudden acceleration or deceleration

Troubleshooting Steps

  1. Step 1: Verify the actual load weight against the hoist capacity
    Load is within rated capacity
  2. Step 2: Check the load cell calibration and zero point
    Load cell reads accurately
  3. Step 3: Ensure smooth lifting to avoid dynamic load spikes
    Load lifts smoothly without spikes

How to Reset

To reset: Remove excess load or recalibrate the sensor, then reset the overload protection.

Source: Demag DR Rope Hoist Manual, Demag Cranes & Components GmbH

Category: Crane