Demag DR-PRO 50t Error Code D019

Demag Crane Major Sensor

Model: DR-PRO 50t | Code: D019

Applicable Systems
DR-PRO 50t

Symptoms

The crane reports a load cell fault. The load weighing sensor is not reading correctly.

Possible Causes

  • Load cell element damaged or degraded
  • Load cell wiring or connector corroded
  • Load cell amplifier or signal conditioner fault

Troubleshooting Steps

  1. Step 1: Test the load cell output signal
    Signal matches the applied load
  2. Step 2: Inspect wiring and connectors for corrosion
    Connections are clean and secure
  3. Step 3: Verify the signal amplifier operation
    Amplifier output matches the load

How to Reset

To reset: Repair or replace the load cell, then recalibrate and clear the fault.

Source: Demag DR Rope Hoist Manual, Demag Cranes & Components GmbH

Category: Crane