Demag DR-PRO 50t Error Code D019

Demag Crane Major Sensor

Model: DR-PRO 50t | Code: D019

Applicable Systems
DR-PRO 50t

Symptoms

The crane reports a load cell fault. The load weighing sensor is not reading correctly.

Possible Causes

  • Load cell element damaged or degraded
  • Load cell wiring or connector corroded
  • Load cell amplifier or signal conditioner fault

Troubleshooting Steps

  1. Step 1: Test the load cell output signal
    Signal matches the applied load
  2. Step 2: Inspect wiring and connectors for corrosion
    Connections are clean and secure
  3. Step 3: Verify the signal amplifier operation
    Amplifier output matches the load

How to Reset

To reset: Repair or replace the load cell, then recalibrate and clear the fault.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Demag DR Rope Hoist Manual, Demag Cranes & Components GmbH