Applicable Systems
R-Series

Symptoms

Discharge air temperature from the airend exceeds 115C (239F). The high-temperature switch (HTT) has opened, triggering an immediate shutdown to protect the airend and oil system.

Possible Causes

  • Dirty oil cooler fins restricting heat transfer and airflow
  • Oil separator element clogged, causing back-pressure and elevated compression temperature
  • Thermostatic bypass valve stuck closed, preventing oil flow through the cooler
  • Ambient temperature exceeds 46C (115F) or the cooler is installed too close to a wall

Troubleshooting Steps

  1. Step 1: Check the oil cooler exterior for dust, oil film, or debris accumulation between the fins
    Blow out the cooler with low-pressure compressed air from the inside outward, or wash with foaming cleaner
  2. Step 2: Monitor the separator differential pressure via the panel gauge or smart controller
    Replace the separator element if differential exceeds 0.8 bar (12 psi) or the runtime exceeds 4000 hours
  3. Step 3: With the compressor running, feel the oil cooler outlet line - it should be warm but not hot
    If the outlet line is cold while the inlet is hot, the thermostatic valve is stuck closed and must be replaced
  4. Step 4: Verify minimum clearances around the compressor - 1 m on sides, 1.5 m above, per installation manual
    Relocate ventilation ducts or add exhaust fans if ambient temperature is consistently above 40C

How to Reset

Reset: The discharge temperature must drop below 95C (203F) before the HTT resets. Press the Reset button on the controller and wait for the 10-minute restart timer.

Common Replacement Parts

  • 2342-4956-00: Oil cooler core, R 37-45 (Aluminum brazed plate, 450x280x65 mm)
  • 2342-4957-00: Separator element, R 37-45 (Flanged, 200 mm OD x 450 mm height)
  • 2342-4958-00: Thermostatic bypass valve (Opens at 75C, 1-inch NPT)

Frequently Asked Questions

  • Q: How long should the separator last?

    Under normal conditions, 4000-6000 runtime hours. In high-dust environments or with poor oil quality, life may drop to 2000 hours.

  • Q: Can a dirty cooler cause permanent damage?

    Yes. Sustained high discharge temperatures degrade the oil, varnish the airend, and can warp the rotors. Clean the cooler at every 1000-hour service.

Source: Ingersoll Rand R-Series Operation and Maintenance Manual, 23425330

Category: Compressor