Kaeser ASD/BS Series Error Code K007

Kaeser Compressor Major Temperature

Model: ASD/BS Series | Code: K007

Applicable Systems
ASD/BS Series

Symptoms

The compressor discharge temperature exceeds 105C (221F), triggering a high-temperature warning alarm. The controller reduces load to prevent oil degradation.

Possible Causes

  • Insufficient cooling airflow due to clogged cooler fins or blocked ventilation
  • Low oil level or degraded oil reducing heat transfer efficiency
  • Ambient temperature exceeding the rated 40C (104F) maximum

Troubleshooting Steps

  1. Step 1: Inspect the air-oil cooler for dirt buildup and clean with compressed air or solvent cleaner
    Airflow through the cooler should be unobstructed; fins should show no clogging
  2. Step 2: Check the oil level sight glass and verify oil is between the MIN and MAX marks
    Add approved compressor oil if level is below MIN
  3. Step 3: Measure the ambient temperature near the compressor intake
    If above 40C, improve room ventilation or consider relocating the intake to a cooler zone

How to Reset

Reset: After the discharge temperature drops below 95C, press the Alarm Reset button on the controller. The alarm clears automatically.

Common Replacement Parts

  • Air-oil cooler cleaning kit: Solvent-based foam cleaner and fin comb (Use quarterly in dusty environments)

Frequently Asked Questions

  • Q: What is the maximum discharge temperature?

    Most rotary screw compressors alarm at 110C and shut down at 120C. Consult the manual for specific thresholds.

  • Q: Can I use automotive oil?

    No. Use only ISO VG 46 synthetic compressor oil approved by the manufacturer to prevent varnish and seal damage.

Source: Service Manual

Category: Compressor