Konecranes CXT 50t Error Code CR05

Konecranes Crane Major Drive

Model: CXT 50t | Code: CR05

Applicable Systems
SMODEX 90t

Symptoms

The crane reports a variable frequency drive alarm. The VFD has detected a fault and disabled the drive.

Possible Causes

  • VFD overcurrent from motor or cable fault
  • VFD overheating from inadequate cooling
  • Input voltage transient or phase loss

Troubleshooting Steps

  1. Step 1: Check the VFD fault log for the specific code
    Fault code is identified
  2. Step 2: Verify VFD cooling fan and heat sink condition
    Cooling is adequate
  3. Step 3: Check input voltage and phase balance
    Voltage is balanced and within range

How to Reset

To reset: Resolve the VFD fault, then reset the drive and test operation.

Source: Konecranes Crane Safety Manual, Konecranes Plc

Category: Crane