Konecranes CXT 50t Error Code CR01

Konecranes Crane Critical Safety

Model: CXT 50t | Code: CR01

Applicable Systems
SMODEX 90t

Symptoms

The crane reports an overload protection trip. The load exceeds the rated capacity and the crane has stopped lifting.

Possible Causes

  • Load weight exceeding the crane rated capacity
  • Load cell or weight sensor calibration error
  • Overload protection setpoint incorrectly configured

Troubleshooting Steps

  1. Step 1: Verify the actual load weight against the crane rated capacity
    Load is within rated capacity
  2. Step 2: Check the load cell calibration and zero point
    Load cell reads accurately
  3. Step 3: Verify the overload protection setpoint
    Setpoint matches the rated capacity

How to Reset

To reset: Remove excess load or recalibrate the sensor, then reset the overload protection.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Konecranes Crane Safety Manual, Konecranes Plc

Category: Crane