Konecranes CXT 50t Error Code CR12

Konecranes Crane Major Control

Model: CXT 50t | Code: CR12

Applicable Systems
SMODEX 90t

Symptoms

The crane reports a synchronization control fault. The dual-girder or multi-motor synchronization has lost coordination.

Possible Causes

  • Motor speed mismatch between synchronized axes
  • Encoder feedback inconsistency between motors
  • Synchronization control parameter error

Troubleshooting Steps

  1. Step 1: Check motor speeds and encoder feedback on both axes
    Speeds match within tolerance
  2. Step 2: Verify the synchronization control parameters
    Parameters are correctly set
  3. Step 3: Test the synchronization function through a travel cycle
    Axes move in sync

How to Reset

To reset: Restore synchronization, then clear the alarm.

Source: Konecranes Crane Safety Manual, Konecranes Plc