Applicable Systems
KR CYBERTECH
Symptoms
Motor overcurrent. The motor current has exceeded the drive's maximum limit. The drive immediately disablesthe motor output.
Possible Causes
- Motor phase-to-phase short circuit
- Motor phase-to-ground short circuit
- Drive output IGBT module failure
- Excessive load or collision causing current spike
Troubleshooting Steps
- Step 1: Check the equipment status and fault indicators to confirm the active fault code
Fault indicator or HMI displays code 125 as active - Step 2: Verify all electrical connections, wiring harnesses, and connector seating
All connections secure, no corrosion, loose pins, or damaged wires - Step 3: Check motor cable connections at drive output terminals for correct phase sequence and tightness
Cables securely connected, phase sequence correct, no loose terminals - Step 4: Measure motor winding insulation resistance with a megger (500V DC minimum)
Insulation resistance above minimum value (typically > 1 Megaohm) - Step 5: Verify drive parameter settings match motor nameplate data (current, voltage, power, RPM)
All motor nameplate parameters correctly entered in drive - Step 6: Inspect motor for mechanical overload, bearing seizure, or driven equipment jam
Motor rotates freely, no mechanical binding or excessive load - Step 7: Reset the fault after fixing the root cause: clear the fault via HMI or power-cycle
Fault clears and drive resumes normal operation without recurrence
How to Reset
To reset: 1) Identify and fix the root cause described in the fault symptoms. 2) Press RESET on the HMI or controller, or power-cycle the equipment. 3) If the fault recurs, contact manufacturer service. Caution: Document the fault code and context before resetting.
Frequently Asked Questions
- Q: What does fault code 125 mean on the KUKA KRC4?
Fault 125 on the KUKA KRC4 indicates: Motor overcurrent. The motor current has exceeded the drive's maximum limit. The drive immediately disables the motor output. Refer to the equipment manual and manufacturer support for specific troubleshooting steps.
- Q: Can I continue operating the equipment with fault 125 active?
No. The equipment has detected a fault condition and has taken protective action (typically stopping or derating). Continuing to operate without fixing the root cause may cause further damage. Always investigate and fix the fault before resuming operation.