Lenze i950 Error Code LSV015

Lenze PLC & VFD Major System

Model: i950 | Code: LSV015

Applicable Systems
i950

Symptoms

The i950 reports a watchdog timeout fault. The system watchdog timer expired without receiving the expected communication or task completion signal.

Possible Causes

  • Host controller communication interrupted or stopped
  • Application task execution exceeded the watchdog timeout period
  • Watchdog timeout setting too short for the actual task cycle time

Troubleshooting Steps

  1. Step 1: Check the host controller communication link status in the drive
    Communication link is active and stable
  2. Step 2: Review the task execution time and compare with the watchdog setting
    Task completes within the watchdog period
  3. Step 3: Increase the watchdog timeout if the task legitimately requires more time
    Watchdog timeout accommodates the task cycle

How to Reset

To reset: Restore communication or fix the task timing, then reset.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Lenze i950 Servo Drive Manual, Lenze SE

Category: PLC & VFD