Lenze i950 Error Code LSV005

Lenze PLC & VFD Major Overload

Model: i950 | Code: LSV005

Applicable Systems
i950

Symptoms

The i950 reports an overload fault. The thermal model calculated I2t exceeded the trip threshold indicating sustained overload.

Possible Causes

  • Load torque exceeds the rated capacity
  • Mechanical binding or friction increasing the load demand
  • Acceleration time too short for the load inertia

Troubleshooting Steps

  1. Step 1: Check the mechanical load for binding, friction, or excessive torque demand
    Load torque is within the rated capacity
  2. Step 2: Increase the acceleration and deceleration times to reduce peak current
    Peak current stays within the thermal model limit
  3. Step 3: If the load genuinely requires more torque, upgrade to a larger unit
    Larger unit handles the load without overload trips

How to Reset

To reset: Resolve the overload condition, wait for thermal model to reset, then restart.

Source: Lenze i950 Servo Drive Manual, Lenze SE

Category: PLC & VFD