Lenze i950 Error Code LSV025

Lenze PLC & VFD Major Motor

Model: i950 | Code: LSV025

Applicable Systems
i950

Symptoms

The i950 reports a motor ground fault. Leakage current to ground was detected in the motor circuit, indicating insulation breakdown.

Possible Causes

  • Motor winding insulation breakdown to the motor frame
  • Motor cable insulation damage exposing conductor to ground
  • Moisture or water ingress in the motor or junction box

Troubleshooting Steps

  1. Step 1: Test the motor winding insulation to ground with a megger
    Insulation resistance is above the minimum threshold
  2. Step 2: Inspect the motor cable for physical damage or water ingress
    Cable insulation is intact and dry
  3. Step 3: Repair or replace any motor or cable with failed insulation
    Ground fault is cleared after repair

How to Reset

To reset: Fix the motor ground fault, then reset the fault and restart.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Lenze i950 Servo Drive Manual, Lenze SE

Category: PLC & VFD