Lenze i950 Error Code LSV026

Lenze PLC & VFD Critical Motor

Model: i950 | Code: LSV026

Applicable Systems
i950

Symptoms

The i950 reports a motor short circuit fault. A short circuit was detected in the motor windings between phases or to ground.

Possible Causes

  • Motor winding phase-to-phase short circuit due to insulation failure
  • Motor winding short to the motor frame or ground
  • Motor terminal box wiring error causing phase short

Troubleshooting Steps

  1. Step 1: Disconnect the motor cable and test winding insulation with a megger
    Insulation resistance is above minimum
  2. Step 2: Measure winding resistance between all phase pairs for balance
    All phase resistances are balanced
  3. Step 3: Repair or replace the motor if windings are shorted
    Motor windings show no short circuits

How to Reset

To reset: Eliminate the motor short circuit, then reset and restart.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Lenze i950 Servo Drive Manual, Lenze SE

Category: PLC & VFD