Lenze i950 Error Code LSV026

Lenze PLC & VFD Critical Motor

Model: i950 | Code: LSV026

Applicable Systems
i950

Symptoms

The i950 reports a motor short circuit fault. A short circuit was detected in the motor windings between phases or to ground.

Possible Causes

  • Motor winding phase-to-phase short circuit due to insulation failure
  • Motor winding short to the motor frame or ground
  • Motor terminal box wiring error causing phase short

Troubleshooting Steps

  1. Step 1: Disconnect the motor cable and test winding insulation with a megger
    Insulation resistance is above minimum
  2. Step 2: Measure winding resistance between all phase pairs for balance
    All phase resistances are balanced
  3. Step 3: Repair or replace the motor if windings are shorted
    Motor windings show no short circuits

How to Reset

To reset: Eliminate the motor short circuit, then reset and restart.

Source: Lenze i950 Servo Drive Manual, Lenze SE