Lenze i950 Error Code LSV016

Lenze PLC & VFD Major EEPROM

Model: i950 | Code: LSV016

Applicable Systems
i950

Symptoms

The i950 reports an EEPROM fault. Parameter data stored in the non-volatile memory failed verification, indicating corruption.

Possible Causes

  • EEPROM write cycle interrupted by power loss
  • EEPROM cell degradation due to excessive write cycles
  • Electrical noise corrupting data during the EEPROM write operation

Troubleshooting Steps

  1. Step 1: Reload the default parameters and reconfigure the drive settings
    Parameters are restored to known-good values
  2. Step 2: Save the parameters to EEPROM and verify the write operation
    EEPROM write completes without error
  3. Step 3: If the error recurs, the EEPROM chip may be defective requiring drive replacement
    New drive stores parameters without errors

How to Reset

To reset: Reload and re-save parameters, then cycle power and restart.

Source: Lenze i950 Servo Drive Manual, Lenze SE

Category: PLC & VFD