Lenze i950 Error Code LSV024

Lenze PLC & VFD Major Motor

Model: i950 | Code: LSV024

Applicable Systems
i950

Symptoms

The i950 reports a motor phase loss fault. One or more motor output phases are missing, causing unbalanced motor operation.

Possible Causes

  • Motor cable disconnected or broken on one phase
  • Motor terminal box loose connection on one phase
  • Drive output phase failure due to semiconductor damage

Troubleshooting Steps

  1. Step 1: Check all motor cable connections at the drive and motor ends
    All phase connections are tight and secure
  2. Step 2: Measure motor winding resistance between all three phases for balance
    All phase resistances are balanced
  3. Step 3: If the drive output is faulty, replace the drive unit
    Drive output is balanced on all three phases

How to Reset

To reset: Restore all three motor output phases, then reset the fault.