Lenze i950 Error Code LSV035

Lenze PLC & VFD Critical Hardware

Model: i950 | Code: LSV035

Applicable Systems
i950

Symptoms

The i950 reports a power module fault. The intelligent power module (IPM) detected an internal failure and tripped.

Possible Causes

  • IPM internal IGBT or freewheeling diode failure
  • IPM gate drive circuit fault preventing proper switching
  • IPM overheat due to excessive switching losses or cooling failure

Troubleshooting Steps

  1. Step 1: Check the IPM for short circuit between output terminals
    IPM shows no short circuit
  2. Step 2: Verify the cooling system is functioning and the heatsink is clean
    Cooling is adequate and heatsink is clean
  3. Step 3: If the IPM is defective, replace the drive unit
    New unit operates with a healthy IPM

How to Reset

To reset: Fix the power module fault or replace the unit, then restart.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Lenze i950 Servo Drive Manual, Lenze SE

Category: PLC & VFD