Lenze i950 Error Code LSV019

Lenze PLC & VFD Major Configuration

Model: i950 | Code: LSV019

Applicable Systems
i950

Symptoms

The i950 reports a configuration mismatch. The drive configuration does not match the connected motor or system parameters.

Possible Causes

  • Motor parameters not set or do not match the actual motor nameplate
  • Control mode setting does not match the application type
  • I/O configuration does not match the external wiring

Troubleshooting Steps

  1. Step 1: Compare the motor parameter settings with the motor nameplate data
    Motor parameters match the nameplate values
  2. Step 2: Verify the control mode and I/O configuration match the application
    Configuration is consistent with the wiring and application
  3. Step 3: Run auto-tuning if supported to automatically detect motor parameters
    Auto-tune completes and parameters are updated

How to Reset

To reset: Correct the configuration mismatch, save, then restart.

Source: Lenze i950 Servo Drive Manual, Lenze SE

Category: PLC & VFD