Lenze i950 Error Code LSV034

Lenze PLC & VFD Major System

Model: i950 | Code: LSV034

Applicable Systems
i950

Symptoms

The i950 reports a speed search failure. The drive could not detect the motor speed during restart of a spinning motor.

Possible Causes

  • Motor speed search parameter not configured correctly
  • Motor was spinning in the wrong direction during restart
  • Speed search algorithm could not converge within the timeout period

Troubleshooting Steps

  1. Step 1: Enable the speed search function and set the correct parameters
    Speed search is properly configured
  2. Step 2: Verify the motor direction before attempting restart
    Motor direction is correct for restart
  3. Step 3: Increase the speed search timeout if the motor inertia is large
    Speed search completes within the extended timeout

How to Reset

To reset: Configure speed search properly, then retry the start.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Lenze i950 Servo Drive Manual, Lenze SE

Category: PLC & VFD