Mitsubishi iQ-R Motion Controller Error Code 1FE0H (Details: 0004H)

Mitsubishi PLC & VFD Minor Error Motion Control

Model: iQ-R Motion Controller (R32MTCPU/R16MTCPU) | Code: 1FE0H (Details: 0004H)

Applicable Systems
MELSEC FX3U MELSEC FX5U FR-A800 FR-A700 MR-J4 iQ-R Motion Controller (R32MTCPU/R16MTCPU)

Symptoms

Machine control setting data incorrect. Interpolation control unit incorrect. The machine does not start. Error code 1FE0H with details code 0004H.

Possible Causes

  • The control unit specified in parameter block does not match the control unit of the machine. The control unit of positioning data does not match the control unit of the machine.

Troubleshooting Steps

  1. Step 1: Match the control unit specified in parameter block with the control unit of the machine. Match the control unit of positioning data with the control unit of the machine.
    Refer to manual for details

How to Reset

Reset using [Rq.2240] Machine error reset command (M43616+32m) or Error reset (SM50). Clear the root cause before resetting.

Source: MELSEC iQ-R Motion Controller Programming Manual IB-0300309-L, Appendix 2 & 3

Category: PLC & VFD