Mitsubishi iQ-R Motion Controller Error Code 1FE0H (Details: 0064H)

Mitsubishi PLC & VFD Minor Error Motion Control

Model: iQ-R Motion Controller (R32MTCPU/R16MTCPU) | Code: 1FE0H (Details: 0064H)

Applicable Systems
MELSEC FX3U MELSEC FX5U FR-A800 FR-A700 MR-J4 iQ-R Motion Controller (R32MTCPU/R16MTCPU)

Symptoms

Machine control setting data incorrect. Auxiliary point/end point setting error (auxiliary point circular). The machine does not start. Error code 1FE0H with details code 0064H.

Possible Causes

  • The address specification does not make an arc at 3D circular interpolation control with auxiliary point specification.

Troubleshooting Steps

  1. Step 1: Correct the point block address specified to the end point/auxiliary point.
    Refer to manual for details

How to Reset

Reset using [Rq.2240] Machine error reset command (M43616+32m) or Error reset (SM50). Clear the root cause before resetting.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: MELSEC iQ-R Motion Controller Programming Manual IB-0300309-L, Appendix 2 & 3