Mitsubishi iQ-R Motion Controller Error Code 1FE1H (Details: 0603H)

Mitsubishi PLC & VFD Moderate Error Motion Control

Model: iQ-R Motion Controller (R32MTCPU/R16MTCPU) | Code: 1FE1H (Details: 0603H)

Applicable Systems
MELSEC FX3U MELSEC FX5U FR-A800 FR-A700 MR-J4 iQ-R Motion Controller (R32MTCPU/R16MTCPU)

Symptoms

Machine configuration error or machine library error. End point overflow. The machine does not start. Error code 1FE1H/30FAH with details code 0603H.

Possible Causes

  • The point block specified in the positioning point is world/base/tool coordinate system, and the specified address is outside the range for 32-bit integer (signed).

Troubleshooting Steps

  1. Step 1: Correct the address of the point block specified in the positioning point, or correct the base translation value setting.
    Refer to manual for details

How to Reset

Reset using [Rq.2240] Machine error reset command (M43616+32m) or Error reset (SM50). Clear the root cause before resetting.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: MELSEC iQ-R Motion Controller Programming Manual IB-0300309-L, Appendix 2 & 3

Category: PLC & VFD