NORD SK Error Code N016

NORD PLC & VFD Major Safety

Model: SK | Code: N016

Applicable Systems
SK

Symptoms

The SK reports a safety function activation. The safety circuit was triggered, removing motor torque and halting the drive.

Possible Causes

  • Safety input signal activated by an external safety relay or E-stop
  • Safety relay wiring fault causing false trigger
  • Safety function configuration does not match the application requirements

Troubleshooting Steps

  1. Step 1: Check the safety input wiring and verify the safety relay status
    Safety relay is in the expected state
  2. Step 2: Verify the safety function configuration parameters in the drive
    Safety configuration matches the application
  3. Step 3: Reset the safety circuit by clearing the E-stop and cycling the safety relay
    Safety function releases and motor torque is restored

How to Reset

To reset: Clear the safety condition and reset the safety relay, then restart.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: NORD SK Drive System Manual, NORD Drives

Category: PLC & VFD