Picanol GTM Error Code P015

Picanol Textile Minor Mechanical

Model: GTM | Code: P015

Applicable Systems
GTM

Symptoms

The weaving machine reports a vibration anomaly. The machine vibration level exceeds the normal range.

Possible Causes

  • Main shaft bearing wear
  • Loose mounting bolts or frame members
  • Unbalanced rotating component

Troubleshooting Steps

  1. Step 1: Check the main shaft bearings
    Bearings are within wear tolerance
  2. Step 2: Inspect and tighten all mounting hardware
    All bolts are tight
  3. Step 3: Verify rotating components are balanced
    Components are balanced within tolerance

How to Reset

To reset: Resolve the vibration issue, then clear the alarm.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Picanol Weaving Machine Manual, Picanol NV

Category: Textile