Applicable Systems
GTM
Symptoms
The weaving machine reports a vibration anomaly. The machine vibration level exceeds the normal range.
Possible Causes
- Main shaft bearing wear
- Loose mounting bolts or frame members
- Unbalanced rotating component
Troubleshooting Steps
- Step 1: Check the main shaft bearings
Bearings are within wear tolerance - Step 2: Inspect and tighten all mounting hardware
All bolts are tight - Step 3: Verify rotating components are balanced
Components are balanced within tolerance
How to Reset
To reset: Resolve the vibration issue, then clear the alarm.
Source: Picanol Weaving Machine Manual, Picanol NV
Category: Textile