Applicable Systems
QSI/QGV Series
Symptoms
Discharge check valve is leaking back to the sump when the compressor is stopped. The sump pressure bleeds down overnight and the compressor short-cycles on startup.
Possible Causes
- Check valve seat damaged by debris or corrosion from acidic condensate
- Check valve spring broken or weakened, failing to close the poppet against back-pressure
- Check valve poppet stuck in the open position by oil varnish or foreign object
Troubleshooting Steps
- Step 1: With the compressor stopped and tank isolated, listen for airflow or hissing at the intake filter
Backflow through the check valve is audible as a rushing sound at the intake silencer - Step 2: Remove the check valve from the discharge line and inspect the poppet, seat, and spring
Replace the spring if free length is <90% of spec. Lap the seat if scoring is minor; replace the valve if seat damage is severe - Step 3: Inspect the valve bore for varnish or debris that could bind the poppet
Clean with solvent and verify the poppet drops freely by gravity when the valve is held vertically - Step 4: Check downstream for sources of debris - replace the discharge line filter if installed
Install a 40-mesh strainer upstream of the check valve if debris is a recurring problem
How to Reset
Reset: After check valve replacement, press Reset on the QSI controller. The alarm clears after a complete stop-start cycle confirms no backflow is detected.
Common Replacement Parts
- 2023-4040-00: Discharge check valve, QSI 200-300 (Spring-loaded poppet, 2-inch NPT, brass)
- 2023-4041-00: Check valve spring (Stainless steel, rated for 10,000 cycles)
- 2023-4042-00: Check valve seat lapping tool (Piloted arbor for 2-inch valves)
Frequently Asked Questions
- Q: Why does my compressor start every hour overnight?
A leaking check valve allows tank pressure to bleed back into the sump and escape through the breather. The pressure drops until the start signal is triggered.
- Q: Can I add a second check valve in parallel?
Not recommended. Instead, replace the faulty valve with a correctly rated unit. Parallel valves can create flow imbalance and water hammer during start-up.
Source: Quincy QSI Series Operation and Maintenance Manual, 2023-OM-100
Category: Compressor