Sullair LS Series Error Code S008

Sullair Compressor Major Pressure

Model: LS Series | Code: S008

Applicable Systems
LS Series

Symptoms

The system failed to unload at the set pressure, causing the safety valve to vent excess air. The controller logs an overpressure event.

Possible Causes

  • Unloader valve stuck closed or solenoid not de-energizing
  • Pressure switch set point drifted higher than the rated working pressure
  • Safety valve spring weakened or set too high

Troubleshooting Steps

  1. Step 1: Test the unloader solenoid by manually toggling load/unload from the controller
    Listen for the solenoid click; measure coil resistance if silent
  2. Step 2: Verify the working pressure setpoint in the controller matches the nameplate rating
    Adjust if the setpoint has drifted above the rated 7-10 bar
  3. Step 3: Inspect the safety valve for signs of leakage, corrosion, or tampering
    Replace if the valve does not reseat cleanly after venting

How to Reset

Reset: Correct the root cause and press Alarm Reset. The safety valve resets automatically once pressure drops below its setpoint.

Common Replacement Parts

  • Unloader valve repair kit: Includes solenoid, piston, and spring (OEM part number required)
  • Safety valve: Set to 10.5 bar for standard compressors (Do not adjust - replace if faulty)

Frequently Asked Questions

  • Q: How often should the safety valve be tested?

    Manually lift the safety valve collar quarterly to verify free movement. Replace every 5 years or if it fails to reseat.

  • Q: What causes unloader valve failure?

    Oil contamination, worn piston seals, or solenoid burnout are the most common causes.

Source: Service Manual

Category: Compressor