Uhlmann Uhlmann Blister Machine Error Code U002

Uhlmann Packaging Major Sealing

Model: Uhlmann Blister Machine | Code: U002

Applicable Systems
Uhlmann Blister Machine

Symptoms

The Uhlmann blister machine displays alarm U002, indicating heat seal temperature anomaly. The sealing station temperature is outside the allowed tolerance, risking weak seals or film damage.

Possible Causes

  • Sealing heater band has failed or burned out, not heating the seal plate to the setpoint
  • Sealing thermocouple has drifted or is loose, causing inaccurate temperature feedback and oscillation
  • Seal plate surface is contaminated with adhesive or film residue, causing uneven heat transfer and weak seals

Troubleshooting Steps

  1. Step 1: Check the sealing heater band resistance and supply voltage
    Heater band resistance matches the nameplate value and the supply voltage is present
  2. Step 2: Calibrate or replace the sealing thermocouple against a reference pyrometer
    Thermocouple reading matches the pyrometer within 3C at the sealing temperature setpoint
  3. Step 3: Inspect and clean the seal plate surface for adhesive or film residue buildup
    Seal plate is clean and smooth with no residue or deposits that would affect heat transfer or seal quality

How to Reset

To reset: 1) Replace the failed heater band. 2) Replace or recalibrate the thermocouple. 3) Clean the seal plate. 4) Press RESET. 5) Verify seal strength with a leak test after a test cycle.

Source: Uhlmann Blister Machine Manual, Uhlmann Pac-Systeme GmbH

Category: Packaging