Applicable Systems
UR3
UR5
UR10
UR3e
UR5e
UR10e
UR16e
UR20
UR30
Symptoms
The power drawn by the Energy Removal Device over a period has exceeded the allowed limit
Possible Causes
- The power drawn by the Energy Removal Device over a period has exceeded the allowed limit
Troubleshooting Steps
- Step 1: Ensure supply is not delivering more than 48V,
Check if the issue is resolved after this step - Step 2: Update software,
Check if the issue is resolved after this step - Step 3: Contact your local Universal Robots service provider for assistance
Check if the issue is resolved after this step
How to Reset
Power cycle the robot controller and perform a complete reboot sequence. If the error persists, update the software to the latest version.
Source: Universal Robots Official Error Codes Directory (https://www.universal-robots.com/manuals/EN/PDF/Shared/ErrorCodes/ErrorCodes.pdf)