Worcester Bosch Greenstar GB162 Error Code WB03

Worcester Bosch Home Boiler Critical Temperature

Model: Greenstar GB162 | Code: WB03

Applicable Systems
Greenstar GB162

Symptoms

The boiler reports an overheat protection trip. The primary heat exchanger temperature has exceeded the safety limit.

Possible Causes

  • Pump failure or insufficient flow through the heat exchanger
  • Air lock in the system preventing circulation
  • System valve closed blocking flow

Troubleshooting Steps

  1. Step 1: Check the primary circulator pump operation
    Pump runs and circulates water
  2. Step 2: Bleed air from the system to remove air locks
    All radiators are free of air
  3. Step 3: Verify all system valves are open
    All valves allow full flow

How to Reset

To reset: Restore flow through the heat exchanger, then press the reset button.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Worcester Bosch Boiler Manual, Worcester Bosch Group

Category: Home Boiler