CID-48-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 48 FMI 5 - Exhaust Gas Temperature Bank 1: Current Below Normal, or Open Circuit |
heavy-equipment |
Major |
View → |
CID-90-FMI-1 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 90 FMI 1 - Crankcase Breather Filter: Data Valid But Below Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-168-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 168 FMI 6 - Lifting Mode Switch: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
451-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 451 FMI 1 - Air Filter Restriction (High) Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
40-15 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 40 FMI 15 - Engine Oil Level Sensor Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
CID-66-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 66 FMI 5 - Engine Brake Solenoid #3: Current Below Normal, or Open Circuit |
heavy-equipment |
Major |
View → |
68-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 68 FMI 13 - Turbocharger Compressor Outlet Temperature Out of Calibration |
heavy-equipment |
Minor |
View → |
261-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 261 FMI 8 - Fuel Pressure (High) Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
CID-10-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 10 FMI 0 - Coolant Loss: Data Valid But Above Normal Operational Range |
heavy-equipment |
Major |
View → |
371-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 371 FMI 18 - Fuel Filter Differential Pressure Switch Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-40-FMI-1 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 40 FMI 1 - Engine Protection Override: Data Valid But Below Normal Operational Range |
heavy-equipment |
Critical |
View → |
CID-13-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 13 FMI 4 - Fuel Temperature: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-87-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 87 FMI 2 - Cylinder Cutout #4: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |
10-4 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 10 FMI 4 - Fuel Pressure Sensor Voltage Below Normal/Shorted Low |
heavy-equipment |
Major |
View → |
78-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 78 FMI 6 - Engine Speed-Timing Sensor (Crankshaft) Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
371-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 371 FMI 1 - Fuel Filter Differential Pressure Switch Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
110-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 1 - Radiator Coolant Temperature Sensor Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
381-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 381 FMI 8 - Engine Air Filter Restriction Switch Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
336-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 336 FMI 18 - Hydraulic Pump Pressure Sensor Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
55-15 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 55 FMI 15 - Injection Actuation Pressure Control Valve (Current) Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
255-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 255 FMI 18 - Fuel Injector (Cylinder 5) Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-130-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 130 FMI 0 - Bucket Cylinder Head Pressure: Data Valid But Above Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-196-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 196 FMI 3 - Work Tool Hour Meter: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-45-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 45 FMI 4 - Turbocharger Speed: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
CID-62-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 62 FMI 6 - EGR Differential Pressure: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Major |
View → |
CID-135-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 135 FMI 4 - Boom Position Sensor: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-183-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 183 FMI 4 - Attachment Identification: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
261-3 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 261 FMI 3 - Fuel Pressure (High) Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
CID-149-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 149 FMI 6 - GPS Altitude: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
CID-85-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 85 FMI 2 - Cylinder Cutout #2: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |
27-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 27 FMI 1 - Atmospheric Pressure Sensor Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
CID-2-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 2 FMI 6 - Engine Coolant Temperature: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Major |
View → |
CID-181-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 181 FMI 2 - Auxiliary Hydraulic Pressure: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
CID-30-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 30 FMI 0 - Transmission Oil Pressure: Data Valid But Above Normal Operational Range |
heavy-equipment |
Major |
View → |
341-2 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 341 FMI 2 - Brake Fluid Level Sensor Data Erratic/Intermittent |
heavy-equipment |
Minor |
View → |
341-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 341 FMI 5 - Brake Fluid Level Sensor Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
CID-67-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 67 FMI 4 - Fan Drive Solenoid: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
251-3 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 251 FMI 3 - Fuel Injector (Cylinder 1) Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
CID-133-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 133 FMI 5 - Left Travel Motor Pressure: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-194-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 194 FMI 6 - Work Tool Load: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
40-17 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 40 FMI 17 - Engine Oil Level Sensor Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
110-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 0 - Radiator Coolant Temperature Sensor Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
321-16 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 321 FMI 16 - Brake Oil Pressure (Low) Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
10-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 10 FMI 1 - Fuel Pressure Sensor Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
26-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 26 FMI 18 - Inlet Manifold Pressure Sensor Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
68-2 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 68 FMI 2 - Turbocharger Compressor Outlet Temperature Data Erratic/Intermittent |
heavy-equipment |
Minor |
View → |
425-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 425 FMI 6 - Hydraulic Oil Level (Low) Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
35-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 35 FMI 13 - Radiator Coolant Level Sensor Out of Calibration |
heavy-equipment |
Minor |
View → |
CID-78-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 78 FMI 4 - Injection Actuation Pressure Control Valve: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
27-17 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 27 FMI 17 - Atmospheric Pressure Sensor Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
461-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 461 FMI 1 - Fuel Water Separator Sensor Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
CID-112-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 112 FMI 3 - Power Train Oil Filter Differential Pressure: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-198-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 198 FMI 5 - Work Tool Filter Status: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-15-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 15 FMI 4 - Fuel Injector #1: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
82-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 82 FMI 13 - Throttle Position Sensor (PWM) Out of Calibration |
heavy-equipment |
Minor |
View → |
CID-51-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 51 FMI 2 - Diesel Particulate Filter Regeneration: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |
CID-51-FMI-1 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 51 FMI 1 - Diesel Particulate Filter Regeneration: Data Valid But Below Normal Operational Range |
heavy-equipment |
Major |
View → |
CID-68-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 68 FMI 6 - Coolant Level: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Major |
View → |
CID-105-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 105 FMI 0 - Fan Speed: Data Valid But Above Normal Operational Range |
heavy-equipment |
Minor |
View → |
5-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 5 FMI 0 - Inlet Manifold Air Temperature Sensor Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
425-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 425 FMI 0 - Hydraulic Oil Level (Low) Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
491-3 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 491 FMI 3 - Transmission Filter Bypass Switch Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
CID-61-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 61 FMI 2 - EGR Temperature: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |
5-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 5 FMI 18 - Inlet Manifold Air Temperature Sensor Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-80-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 80 FMI 2 - Camshaft Position Sensor: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Critical |
View → |
CID-121-FMI-1 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 121 FMI 1 - Steering Pump Pressure: Data Valid But Below Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-188-FMI-8 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 188 FMI 8 - Work Tool Pump Pressure: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Minor |
View → |
CID-147-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 147 FMI 3 - GPS Position Latitude: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-88-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 88 FMI 5 - Cylinder Cutout #5: Current Below Normal, or Open Circuit |
heavy-equipment |
Major |
View → |
1-3 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 1 FMI 3 - Mechanical Engine Speed Sensor Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
CID-173-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 173 FMI 4 - Auto Dig Switch: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
5-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 5 FMI 5 - Inlet Manifold Air Temperature Sensor Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
CID-104-FMI-8 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 104 FMI 8 - Actual Engine Torque: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Minor |
View → |
261-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 261 FMI 5 - Fuel Pressure (High) Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
381-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 381 FMI 18 - Engine Air Filter Restriction Switch Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-109-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 109 FMI 5 - Fuel Filter Differential Pressure: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-12-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 12 FMI 4 - Boost Pressure: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |