26-16 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 26 FMI 16 - Inlet Manifold Pressure Sensor Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-171-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 171 FMI 2 - High Speed Travel Switch: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
CID-45-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 45 FMI 2 - Turbocharger Speed: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |
CID-181-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 181 FMI 5 - Auxiliary Hydraulic Pressure: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
2-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 2 FMI 6 - Engine Speed-Timing Sensor Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
52-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 52 FMI 8 - Injection Actuation Pressure Sensor (Rail) Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
CID-132-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 132 FMI 4 - Swing Motor Pressure: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
261-17 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 261 FMI 17 - Fuel Pressure (High) Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
CID-32-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 32 FMI 3 - Brake Oil Pressure: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
CID-133-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 133 FMI 4 - Left Travel Motor Pressure: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
58-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 58 FMI 1 - Analog Temperature Sensor Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
CID-70-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 70 FMI 0 - Engine Load Factor: Data Valid But Above Normal Operational Range |
heavy-equipment |
Minor |
View → |
425-4 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 425 FMI 4 - Hydraulic Oil Level (Low) Voltage Below Normal/Shorted Low |
heavy-equipment |
Major |
View → |
CID-80-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 80 FMI 0 - Camshaft Position Sensor: Data Valid But Above Normal Operational Range |
heavy-equipment |
Critical |
View → |
CID-94-FMI-8 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 94 FMI 8 - Engine Run Time: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Minor |
View → |
CID-164-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 164 FMI 5 - Pedal Position #2: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-164-FMI-8 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 164 FMI 8 - Pedal Position #2: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Minor |
View → |
3-4 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 3 FMI 4 - Injection Actuation Pressure Sensor Voltage Below Normal/Shorted Low |
heavy-equipment |
Major |
View → |
93-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 93 FMI 6 - Fuel Injection Pump Solenoid Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
55-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 55 FMI 0 - Injection Actuation Pressure Control Valve (Current) Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
254-17 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 254 FMI 17 - Fuel Injector (Cylinder 4) Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
11-17 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 11 FMI 17 - Throttle Position Sensor Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
CID-18-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 18 FMI 5 - Fuel Injector #4: Current Below Normal, or Open Circuit |
heavy-equipment |
Major |
View → |
431-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 431 FMI 8 - Brake Fluid Level (Low) Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
5-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 5 FMI 6 - Inlet Manifold Air Temperature Sensor Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
291-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 291 FMI 6 - Transmission Temperature Sensor Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
CID-31-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 31 FMI 4 - Steering Oil Pressure: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-48-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 48 FMI 5 - Exhaust Gas Temperature Bank 1: Current Below Normal, or Open Circuit |
heavy-equipment |
Major |
View → |
CID-90-FMI-1 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 90 FMI 1 - Crankcase Breather Filter: Data Valid But Below Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-168-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 168 FMI 6 - Lifting Mode Switch: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
451-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 451 FMI 1 - Air Filter Restriction (High) Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
40-15 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 40 FMI 15 - Engine Oil Level Sensor Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
CID-66-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 66 FMI 5 - Engine Brake Solenoid #3: Current Below Normal, or Open Circuit |
heavy-equipment |
Major |
View → |
68-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 68 FMI 13 - Turbocharger Compressor Outlet Temperature Out of Calibration |
heavy-equipment |
Minor |
View → |
261-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 261 FMI 8 - Fuel Pressure (High) Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
CID-10-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 10 FMI 0 - Coolant Loss: Data Valid But Above Normal Operational Range |
heavy-equipment |
Major |
View → |
371-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 371 FMI 18 - Fuel Filter Differential Pressure Switch Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-40-FMI-1 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 40 FMI 1 - Engine Protection Override: Data Valid But Below Normal Operational Range |
heavy-equipment |
Critical |
View → |
CID-13-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 13 FMI 4 - Fuel Temperature: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-87-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 87 FMI 2 - Cylinder Cutout #4: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |
371-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 371 FMI 1 - Fuel Filter Differential Pressure Switch Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
110-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 1 - Radiator Coolant Temperature Sensor Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
381-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 381 FMI 8 - Engine Air Filter Restriction Switch Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
336-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 336 FMI 18 - Hydraulic Pump Pressure Sensor Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
55-15 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 55 FMI 15 - Injection Actuation Pressure Control Valve (Current) Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
255-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 255 FMI 18 - Fuel Injector (Cylinder 5) Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-130-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 130 FMI 0 - Bucket Cylinder Head Pressure: Data Valid But Above Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-45-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 45 FMI 4 - Turbocharger Speed: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
CID-62-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 62 FMI 6 - EGR Differential Pressure: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Major |
View → |
CID-135-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 135 FMI 4 - Boom Position Sensor: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-183-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 183 FMI 4 - Attachment Identification: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
261-3 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 261 FMI 3 - Fuel Pressure (High) Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
CID-149-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 149 FMI 6 - GPS Altitude: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
CID-85-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 85 FMI 2 - Cylinder Cutout #2: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |
27-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 27 FMI 1 - Atmospheric Pressure Sensor Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
CID-2-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 2 FMI 6 - Engine Coolant Temperature: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Major |
View → |
CID-30-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 30 FMI 0 - Transmission Oil Pressure: Data Valid But Above Normal Operational Range |
heavy-equipment |
Major |
View → |
341-2 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 341 FMI 2 - Brake Fluid Level Sensor Data Erratic/Intermittent |
heavy-equipment |
Minor |
View → |
341-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 341 FMI 5 - Brake Fluid Level Sensor Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
CID-67-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 67 FMI 4 - Fan Drive Solenoid: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
251-3 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 251 FMI 3 - Fuel Injector (Cylinder 1) Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
CID-133-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 133 FMI 5 - Left Travel Motor Pressure: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-194-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 194 FMI 6 - Work Tool Load: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
40-17 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 40 FMI 17 - Engine Oil Level Sensor Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
110-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 0 - Radiator Coolant Temperature Sensor Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
321-16 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 321 FMI 16 - Brake Oil Pressure (Low) Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
10-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 10 FMI 1 - Fuel Pressure Sensor Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
26-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 26 FMI 18 - Inlet Manifold Pressure Sensor Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
68-2 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 68 FMI 2 - Turbocharger Compressor Outlet Temperature Data Erratic/Intermittent |
heavy-equipment |
Minor |
View → |
425-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 425 FMI 6 - Hydraulic Oil Level (Low) Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
35-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 35 FMI 13 - Radiator Coolant Level Sensor Out of Calibration |
heavy-equipment |
Minor |
View → |
CID-78-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 78 FMI 4 - Injection Actuation Pressure Control Valve: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
27-17 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 27 FMI 17 - Atmospheric Pressure Sensor Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
461-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 461 FMI 1 - Fuel Water Separator Sensor Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
CID-112-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 112 FMI 3 - Power Train Oil Filter Differential Pressure: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-15-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 15 FMI 4 - Fuel Injector #1: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
CID-51-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 51 FMI 2 - Diesel Particulate Filter Regeneration: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |