421-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 421 FMI 6 - Transmission Oil Level (Low) Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
CID-117-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 117 FMI 6 - Swing Brake Oil Pressure: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Major |
View → |
61-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 61 FMI 6 - Alternator (Field Current) Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
381-2 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 381 FMI 2 - Engine Air Filter Restriction Switch Data Erratic/Intermittent |
heavy-equipment |
Minor |
View → |
CID-76-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 76 FMI 3 - Fuel Injection Timing: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
252-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 252 FMI 6 - Fuel Injector (Cylinder 2) Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
CID-156-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 156 FMI 2 - Operator Presence: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |
CID-128-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 128 FMI 4 - Stick Cylinder Head Pressure: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-79-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 79 FMI 4 - Engine Speed Sensor: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Critical |
View → |
58-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 58 FMI 18 - Analog Temperature Sensor Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
5-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 5 FMI 13 - Inlet Manifold Air Temperature Sensor Out of Calibration |
heavy-equipment |
Minor |
View → |
CID-1-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 1 FMI 2 - Engine Oil Pressure: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |
CID-7-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 7 FMI 3 - Intake Manifold Air Temperature: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
68-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 68 FMI 0 - Turbocharger Compressor Outlet Temperature Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
CID-16-FMI-1 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 16 FMI 1 - Fuel Injector #2: Data Valid But Below Normal Operational Range |
heavy-equipment |
Major |
View → |
271-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 271 FMI 18 - Transmission Oil Pressure Sensor Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-164-FMI-13 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 164 FMI 13 - Pedal Position #2: Out of Calibration |
heavy-equipment |
Minor |
View → |
CID-91-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 91 FMI 3 - Engine Serial Number: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
17-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 17 FMI 6 - Alternator (Battery Voltage) Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
401-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 401 FMI 5 - Alternator Not Charging Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
CID-15-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 15 FMI 3 - Fuel Injector #1: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
CID-75-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 75 FMI 3 - Actual Throttle Position: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
CID-74-FMI-8 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 74 FMI 8 - Desired Throttle Position: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Major |
View → |
CID-144-FMI-8 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 144 FMI 8 - Swing Angle: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Minor |
View → |
252-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 252 FMI 0 - Fuel Injector (Cylinder 2) Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
CID-36-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 36 FMI 2 - Air Conditioning Pressure: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
241-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 241 FMI 1 - Engine Speed-Timing Sensor (Camshaft) Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
351-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 351 FMI 18 - Radiator Coolant Pressure Sensor Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
58-4 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 58 FMI 4 - Analog Temperature Sensor Voltage Below Normal/Shorted Low |
heavy-equipment |
Major |
View → |
10-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 10 FMI 8 - Fuel Pressure Sensor Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
291-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 291 FMI 0 - Transmission Temperature Sensor Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
351-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 351 FMI 13 - Radiator Coolant Pressure Sensor Out of Calibration |
heavy-equipment |
Minor |
View → |
CID-162-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 162 FMI 3 - Joystick Position #4: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
336-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 336 FMI 8 - Hydraulic Pump Pressure Sensor Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
4-4 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 4 FMI 4 - Engine Coolant Temperature Sensor Voltage Below Normal/Shorted Low |
heavy-equipment |
Major |
View → |
CID-167-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 167 FMI 4 - Travel Mode Switch: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-69-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 69 FMI 5 - Fuel Level: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-7-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 7 FMI 4 - Intake Manifold Air Temperature: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-115-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 115 FMI 2 - Final Drive Oil Temperature: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
CID-187-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 187 FMI 5 - Attachment Direction: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
41-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 41 FMI 6 - Air Inlet Heater Relay Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
1-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 1 FMI 1 - Mechanical Engine Speed Sensor Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
CID-6-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 6 FMI 4 - Engine Oil Temperature: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
CID-137-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 137 FMI 4 - Bucket Position Sensor: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-38-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 38 FMI 3 - Starter Relay: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
415-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 415 FMI 8 - Engine Oil Level (Low) Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
190-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 190 FMI 1 - Engine Speed (RPM) Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
CID-159-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 159 FMI 4 - Joystick Position #1: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-193-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 193 FMI 3 - Work Tool Position: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
20-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 20 FMI 5 - Injection Actuation Pressure Control Valve Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
CID-62-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 62 FMI 4 - EGR Differential Pressure: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
227-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 227 FMI 0 - Injection Actuation Pressure (Low) Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
CID-15-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 15 FMI 0 - Fuel Injector #1: Data Valid But Above Normal Operational Range |
heavy-equipment |
Major |
View → |
CID-182-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 182 FMI 3 - Auxiliary Hydraulic Flow: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
20-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 20 FMI 1 - Injection Actuation Pressure Control Valve Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
371-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 371 FMI 0 - Fuel Filter Differential Pressure Switch Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
401-2 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 401 FMI 2 - Alternator Not Charging Data Erratic/Intermittent |
heavy-equipment |
Minor |
View → |
6-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 6 FMI 1 - Engine Speed-Timing Sensor (Duty Cycle) Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
44-16 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 44 FMI 16 - Engine Warning Indicator Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-79-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 79 FMI 5 - Engine Speed Sensor: Current Below Normal, or Open Circuit |
heavy-equipment |
Critical |
View → |
421-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 421 FMI 13 - Transmission Oil Level (Low) Out of Calibration |
heavy-equipment |
Minor |
View → |
291-17 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 291 FMI 17 - Transmission Temperature Sensor Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
CID-124-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 124 FMI 6 - Pilot Pressure: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
CID-198-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 198 FMI 3 - Work Tool Filter Status: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-143-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 143 FMI 4 - Bucket Angle: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-43-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 43 FMI 6 - High Idle Speed: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Major |
View → |
CID-100-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 100 FMI 3 - Average Fuel Rate: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-66-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 66 FMI 3 - Engine Brake Solenoid #3: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
271-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 271 FMI 8 - Transmission Oil Pressure Sensor Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
CID-195-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 195 FMI 4 - Work Tool Cycle Count: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-58-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 58 FMI 6 - DEF Pump: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Major |
View → |
271-16 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 271 FMI 16 - Transmission Oil Pressure Sensor Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-127-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 127 FMI 6 - Boom Cylinder Rod Pressure: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
CID-90-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 90 FMI 0 - Crankcase Breather Filter: Data Valid But Above Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-10-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 10 FMI 3 - Coolant Loss: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
2-4 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 2 FMI 4 - Engine Speed-Timing Sensor Voltage Below Normal/Shorted Low |
heavy-equipment |
Major |
View → |
CID-142-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 142 FMI 6 - Stick Angle: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |