71-16 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 71 FMI 16 - Fuel Injection Quantity Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
241-3 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 241 FMI 3 - Engine Speed-Timing Sensor (Camshaft) Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
CID-150-FMI-0 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 150 FMI 0 - GPS Speed: Data Valid But Above Normal Operational Range |
heavy-equipment |
Minor |
View → |
421-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 421 FMI 5 - Transmission Oil Level (Low) Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
CID-43-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 43 FMI 4 - High Idle Speed: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
CID-30-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 30 FMI 2 - Transmission Oil Pressure: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |
CID-118-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 118 FMI 4 - Service Brake Oil Pressure: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
391-15 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 391 FMI 15 - Hydraulic Oil Temperature Sensor Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
253-17 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 253 FMI 17 - Fuel Injector (Cylinder 3) Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
CID-131-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 131 FMI 5 - Bucket Cylinder Rod Pressure: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-86-FMI-1 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 86 FMI 1 - Cylinder Cutout #3: Data Valid But Below Normal Operational Range |
heavy-equipment |
Major |
View → |
58-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 58 FMI 8 - Analog Temperature Sensor Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
CID-53-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 53 FMI 5 - SCR Dosing Unit: Current Below Normal, or Open Circuit |
heavy-equipment |
Major |
View → |
42-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 42 FMI 18 - Engine Oil Temperature Sensor Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
71-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 71 FMI 0 - Fuel Injection Quantity Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
491-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 491 FMI 1 - Transmission Filter Bypass Switch Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
58-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 58 FMI 5 - Analog Temperature Sensor Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
41-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 41 FMI 0 - Air Inlet Heater Relay Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
CID-61-FMI-1 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 61 FMI 1 - EGR Temperature: Data Valid But Below Normal Operational Range |
heavy-equipment |
Major |
View → |
CID-55-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 55 FMI 4 - DEF Tank Temperature: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-115-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 115 FMI 4 - Final Drive Oil Temperature: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-55-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 55 FMI 3 - DEF Tank Temperature: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-150-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 150 FMI 4 - GPS Speed: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
227-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 227 FMI 5 - Injection Actuation Pressure (Low) Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
CID-42-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 42 FMI 6 - Low Idle Speed: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Major |
View → |
CID-49-FMI-8 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 49 FMI 8 - Exhaust Gas Temperature Bank 2: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Major |
View → |
17-17 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 17 FMI 17 - Alternator (Battery Voltage) Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
4-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 4 FMI 5 - Engine Coolant Temperature Sensor Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
110-16 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 16 - Radiator Coolant Temperature Sensor Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-119-FMI-8 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 119 FMI 8 - Parking Brake Oil Pressure: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Major |
View → |
CID-54-FMI-13 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 54 FMI 13 - SCR Catalyst Temperature: Out of Calibration |
heavy-equipment |
Major |
View → |
11-16 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 11 FMI 16 - Throttle Position Sensor Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-5-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 5 FMI 4 - Battery Voltage: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
42-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 42 FMI 0 - Engine Oil Temperature Sensor Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
CID-121-FMI-5 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 121 FMI 5 - Steering Pump Pressure: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-77-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 77 FMI 3 - Injection Actuation Pressure: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Critical |
View → |
6-4 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 6 FMI 4 - Engine Speed-Timing Sensor (Duty Cycle) Voltage Below Normal/Shorted Low |
heavy-equipment |
Major |
View → |
281-16 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 281 FMI 16 - Transmission Speed Sensor Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
371-3 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 371 FMI 3 - Fuel Filter Differential Pressure Switch Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
CID-125-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 125 FMI 3 - Main Relief Pressure: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
421-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 421 FMI 6 - Transmission Oil Level (Low) Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
CID-117-FMI-6 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 117 FMI 6 - Swing Brake Oil Pressure: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Major |
View → |
351-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 351 FMI 5 - Radiator Coolant Pressure Sensor Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
61-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 61 FMI 6 - Alternator (Field Current) Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
381-2 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 381 FMI 2 - Engine Air Filter Restriction Switch Data Erratic/Intermittent |
heavy-equipment |
Minor |
View → |
CID-76-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 76 FMI 3 - Fuel Injection Timing: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
441-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 441 FMI 13 - Engine Warning Indicator Circuit Out of Calibration |
heavy-equipment |
Minor |
View → |
252-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 252 FMI 6 - Fuel Injector (Cylinder 2) Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
CID-156-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 156 FMI 2 - Operator Presence: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |
CID-128-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 128 FMI 4 - Stick Cylinder Head Pressure: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-79-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 79 FMI 4 - Engine Speed Sensor: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Critical |
View → |
58-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 58 FMI 18 - Analog Temperature Sensor Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
5-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 5 FMI 13 - Inlet Manifold Air Temperature Sensor Out of Calibration |
heavy-equipment |
Minor |
View → |
CID-1-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 1 FMI 2 - Engine Oil Pressure: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |
CID-7-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 7 FMI 3 - Intake Manifold Air Temperature: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
68-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 68 FMI 0 - Turbocharger Compressor Outlet Temperature Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
CID-16-FMI-1 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 16 FMI 1 - Fuel Injector #2: Data Valid But Below Normal Operational Range |
heavy-equipment |
Major |
View → |
93-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 93 FMI 8 - Fuel Injection Pump Solenoid Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
271-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 271 FMI 18 - Transmission Oil Pressure Sensor Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
CID-164-FMI-13 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 164 FMI 13 - Pedal Position #2: Out of Calibration |
heavy-equipment |
Minor |
View → |
CID-91-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 91 FMI 3 - Engine Serial Number: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
17-6 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 17 FMI 6 - Alternator (Battery Voltage) Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
401-5 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 401 FMI 5 - Alternator Not Charging Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
CID-66-FMI-4 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 66 FMI 4 - Engine Brake Solenoid #3: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
CID-15-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 15 FMI 3 - Fuel Injector #1: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
CID-75-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 75 FMI 3 - Actual Throttle Position: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
CID-74-FMI-8 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 74 FMI 8 - Desired Throttle Position: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Major |
View → |
CID-144-FMI-8 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 144 FMI 8 - Swing Angle: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Minor |
View → |
252-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 252 FMI 0 - Fuel Injector (Cylinder 2) Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
CID-36-FMI-2 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 36 FMI 2 - Air Conditioning Pressure: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
241-1 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 241 FMI 1 - Engine Speed-Timing Sensor (Camshaft) Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
351-18 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 351 FMI 18 - Radiator Coolant Pressure Sensor Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
58-4 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 58 FMI 4 - Analog Temperature Sensor Voltage Below Normal/Shorted Low |
heavy-equipment |
Major |
View → |
10-8 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 10 FMI 8 - Fuel Pressure Sensor Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
291-0 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 291 FMI 0 - Transmission Temperature Sensor Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
351-13 |
Caterpillar |
Caterpillar Heavy Equipment
|
Caterpillar CID 351 FMI 13 - Radiator Coolant Pressure Sensor Out of Calibration |
heavy-equipment |
Minor |
View → |
CID-162-FMI-3 |
Caterpillar |
CAT Electronic Control Module
|
Caterpillar CID 162 FMI 3 - Joystick Position #4: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |