Applicable Systems
CPX-FVDA-P
Symptoms
The valve terminal reports high oil content in the air supply. The air supply contains excessive lubricant.
Possible Causes
- Lubricator setting too high
- Oil mist separator saturated
- Compressor oil carry-over into the air system
Troubleshooting Steps
- Step 1: Check and adjust the lubricator setting
Oil output is at the correct level - Step 2: Inspect and replace the oil mist separator
Separator is clean and effective - Step 3: Verify compressor oil carry-over is within limits
Air quality meets the standard
How to Reset
To reset: Correct the air quality issue, then clear the alarm.
Comments (0)
Share your experience to help others facing the same problem.
Leave a Comment
Source: Festo Valve Terminal Manual, Festo AG & Co. KG
Category: Hydraulic & Pneumatic
No comments yet. Be the first to share your experience!