Applicable Systems
CPX-FVDA-P

Symptoms

The valve terminal reports high oil content in the air supply. The air supply contains excessive lubricant.

Possible Causes

  • Lubricator setting too high
  • Oil mist separator saturated
  • Compressor oil carry-over into the air system

Troubleshooting Steps

  1. Step 1: Check and adjust the lubricator setting
    Oil output is at the correct level
  2. Step 2: Inspect and replace the oil mist separator
    Separator is clean and effective
  3. Step 3: Verify compressor oil carry-over is within limits
    Air quality meets the standard

How to Reset

To reset: Correct the air quality issue, then clear the alarm.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Festo Valve Terminal Manual, Festo AG & Co. KG

Category: Hydraulic & Pneumatic