Applicable Systems
Power Wave ACDC1000SD
Symptoms
The lubrication system reports a distributor fault. A metering or distribution valve is not functioning correctly.
Possible Causes
- Distributor valve piston stuck from contamination
- Valve spring broken or fatigued
- Valve inlet or outlet blocked
Troubleshooting Steps
- Step 1: Disassemble and inspect the distributor valve
Piston moves freely after cleaning - Step 2: Check the valve spring condition
Spring is intact with correct tension - Step 3: Verify inlet and outlet are clear
Oil flows through the valve correctly
How to Reset
To reset: Repair or replace the distributor valve, then clear the alarm.
Comments (0)
Share your experience to help others facing the same problem.
Leave a Comment
Source: Lincoln Lubrication System Manual, Lincoln Industrial
Category: Hydraulic & Pneumatic