Rexroth IndraDrive HCS Error Code F8069

Rexroth PLC & VFD Major Hardware

Model: IndraDrive HCS | Code: F8069

Applicable Systems
EFC FEX FEI HNC

Symptoms

+/-15V supply fault. The internal +/-15V DC power supply rail for analog circuits is out of specification. Analog inputs and encoder signal conditioning may be affected.

Possible Causes

  • Internal power supply component failure on control board
  • Short circuit on the +/-15V rail from external wiring
  • Control board component degradation
  • Power supply overload from too many analog sensors

Troubleshooting Steps

  1. Step 1: Check all external analog input/output wiring for short circuits
    No continuity between analog signal wires and ground or each other
  2. Step 2: Disconnect all external analog devices and restart the drive
    If F8069 clears, an external device was loading the +/-15V rail
  3. Step 3: If F8069 persists with no external load, the internal power supply has failed
    Control board replacement required
  4. Step 4: Replace control module
    New module provides stable +/-15V rails

How to Reset

1) Disconnect all analog I/O. 2) Restart drive. 3) If fault clears, find and fix the shorted external device. 4) If fault persists, replace control module.

Frequently Asked Questions

  • Q: What devices use the +/-15V supply?

    Analog sensors (pressure, temperature, position), analog command signals (0-10V, 4-20mA), and encoder signal conditioning circuits.

  • Q: Can I test the +/-15V rail?

    With the drive powered on and external loads disconnected, measure between the +/-15V test points on the control board. Readings should be within +/-0.5V of nominal.

Source: Rexroth IndraDrive HCS/HMS Fault Code List, Bosch Rexroth AG

Category: PLC & VFD