Applicable Systems
PSE200/PSE201

Symptoms

The pneumatic system reports low air supply pressure. The compressed air pressure is below the minimum operating threshold.

Possible Causes

  • Air compressor capacity insufficient or offline
  • Air line leak or restriction in the distribution system
  • Air filter regulator clogged or misadjusted

Troubleshooting Steps

  1. Step 1: Check the main air supply pressure at the system inlet
    Pressure meets the minimum 5 bar requirement
  2. Step 2: Inspect air lines and fittings for leaks
    No leaks detected
  3. Step 3: Clean or replace the air filter regulator
    Filter is clean and regulator delivers correct pressure

How to Reset

To reset: Restore adequate air pressure, then clear the alarm.

Source: SMC Pneumatic Equipment Manual, SMC Corporation

Category: Hydraulic & Pneumatic