Applicable Systems
PSE200/PSE201

Symptoms

The pneumatic system reports low air supply pressure. The compressed air pressure is below the minimum operating threshold.

Possible Causes

  • Air compressor capacity insufficient or offline
  • Air line leak or restriction in the distribution system
  • Air filter regulator clogged or misadjusted

Troubleshooting Steps

  1. Step 1: Check the main air supply pressure at the system inlet
    Pressure meets the minimum 5 bar requirement
  2. Step 2: Inspect air lines and fittings for leaks
    No leaks detected
  3. Step 3: Clean or replace the air filter regulator
    Filter is clean and regulator delivers correct pressure

How to Reset

To reset: Restore adequate air pressure, then clear the alarm.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: SMC Pneumatic Equipment Manual, SMC Corporation