Applicable Systems
PSE200/PSE201

Symptoms

The pneumatic system reports a tubing rupture. An air line or tube has burst or developed a leak.

Possible Causes

  • Tube degraded from UV or chemical exposure
  • Tube chafed against a sharp edge or fitting
  • Excessive pressure exceeding the tube rating

Troubleshooting Steps

  1. Step 1: Inspect the tubing for visible damage or cracks
    Damaged section is identified
  2. Step 2: Verify the operating pressure is within the tube rating
    Pressure is within the rated value
  3. Step 3: Replace the damaged tube and route to prevent chafing
    New tube is secure and protected

How to Reset

To reset: Replace the damaged tubing, then clear the alarm.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: SMC Pneumatic Equipment Manual, SMC Corporation

Category: Hydraulic & Pneumatic