Applicable Systems
Pack 301

Symptoms

The packaging machine reports a vacuum pressure anomaly. The vacuum level is outside the normal operating range.

Possible Causes

  • Vacuum pump performance degraded
  • Vacuum line leak or filter clogged
  • Vacuum sensor calibration drift

Troubleshooting Steps

  1. Step 1: Check vacuum pump operation and performance
    Pump achieves the required vacuum level
  2. Step 2: Inspect vacuum lines and connections for leaks
    No leaks detected in vacuum circuit
  3. Step 3: Verify vacuum sensor calibration against a reference
    Sensor reads accurately

How to Reset

To reset: Restore correct vacuum level, then clear the alarm on the HMI.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Bosch Packaging Machine Manual, Bosch Packaging Technology

Category: Packaging