Applicable Systems
Engel Victus

Symptoms

The injection molding machine reports an injection speed deviation. The actual injection speed differs from the setpoint.

Possible Causes

  • Injection flow control valve drift
  • Hydraulic pressure insufficient for the speed
  • Encoder feedback inconsistency

Troubleshooting Steps

  1. Step 1: Verify the injection flow control valve
    Valve responds correctly to commands
  2. Step 2: Check hydraulic pressure adequacy
    Pressure supports the required speed
  3. Step 3: Verify encoder feedback signal
    Signal is clean and accurate

How to Reset

To reset: Correct the injection speed, then clear the alarm.

Source: Engel Injection Molding Machine Manual, Engel Austria GmbH

Category: Injection Molding