Applicable Systems
Engel Victus

Symptoms

The injection molding machine reports an injection speed deviation. The actual injection speed differs from the setpoint.

Possible Causes

  • Injection flow control valve drift
  • Hydraulic pressure insufficient for the speed
  • Encoder feedback inconsistency

Troubleshooting Steps

  1. Step 1: Verify the injection flow control valve
    Valve responds correctly to commands
  2. Step 2: Check hydraulic pressure adequacy
    Pressure supports the required speed
  3. Step 3: Verify encoder feedback signal
    Signal is clean and accurate

How to Reset

To reset: Correct the injection speed, then clear the alarm.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Engel Injection Molding Machine Manual, Engel Austria GmbH

Category: Injection Molding