Applicable Systems
Engel Victus
Symptoms
The injection molding machine reports an injection speed deviation. The actual injection speed differs from the setpoint.
Possible Causes
- Injection flow control valve drift
- Hydraulic pressure insufficient for the speed
- Encoder feedback inconsistency
Troubleshooting Steps
- Step 1: Verify the injection flow control valve
Valve responds correctly to commands - Step 2: Check hydraulic pressure adequacy
Pressure supports the required speed - Step 3: Verify encoder feedback signal
Signal is clean and accurate
How to Reset
To reset: Correct the injection speed, then clear the alarm.
Comments (0)
Share your experience to help others facing the same problem.
Leave a Comment
Source: Engel Injection Molding Machine Manual, Engel Austria GmbH
Category: Injection Molding
No comments yet. Be the first to share your experience!